Assembly & Test Cell for the Production of Complex Filter Assemblies

Each workstation provides automatic or semi-automatic assembly.

All nine stations provide interlocks and check sensors to ensure only correct assemblies can progress from one station to another.

All threaded fastenings including screws are tightened using DC electric torque and angle tools.

The 2 Main sub assemblies are engraved with product code numbers.

Each station includes parts presentation and Quarantine chutes for any failed components.

Test equipment at the first station measures the open and closed flow capacity of every assembly.

Leak test equipment at the last station measures the leak rate of every part at pressure (Hydrogen trace gas system) and the leak rate under vacuum (Helium Mass Spectrometer System).